HOW TO FIND IP ADDRESS ON HMC PORTS

You must first put the physical control panel in manual operating mode before you can select or activate certain functions.
To put the physical control panel in manual operating mode, do the following:
1. Use the Increment button to scroll to function 02.

2. 0 2 _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3. Press Enter to start function 02.

4. Press Enter again to move to the second character on the function 02 menu. The current system operating mode is displayed with a pointer, as shown in the following example:
5. 0 2 _ _ B _ _ N < _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ P _ _ _

6. Use the Increment button to scroll through the system operating modes, and select M for manual, as shown in the following example:

7. 0 2 _ _ B _ _ M < _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ P _ _ _
8. Press Enter to select the system operating mode.

9. Press Enter again to exit function 02.
The control panel is in manual operating mode.



Function 30: Service processor IP address and port location

This function displays the service processor IP address and port location. This function is available only in the manual operating mode and from power on standby.
Note: If IPv6 is displayed on the control panel, then the service processor's network ports are configured with IPv6 IP addresses. There are not enough characters on the control panel to display the entire address.

So to get to this function , you have to use increment Key to reach 30 and then press enter key to enter the function 30 and reach 00 to get IP address on HMC1 port and 01 to get IP address on HMC2 port.